摘 要 目的 人血液不同成份的吸收光谱不一。在激光照射血液疗法中,选择最佳波 长进行研究。方法 用752C紫外可见分光光度计进行人血液不同成份吸收光谱的测试。结果 血清、血浆、血红蛋白、白蛋白、红细胞、淋巴细胞、血小板的吸收光谱各有差异,吸收峰值 位置亦不一致。 各成份在200~300 nm的紫外部分吸收率最高,在红外部份吸收率最低,并逐 渐下降。结论 为激光照射血液治疗疾病提供激光波长选择的依据。 关键词 血液;激光/治疗应用;光谱分析;分光光度测定法,红外线;分光光度测定法,紫外 线 中图号 R318.03;R331.11
Absorption Spectrum of Blood Components in Man Lin Shangzhong,Chen Rong,Xu Shaofeng.Fujian People's Hosptal,Fuzhou,350004 Abstract Objective Absorption spectrum of human blood components is distinctive.In the blood irradiation therapy,the study aimed at appropriate wavelength.Methods The absorption spectrum in different components of human beings were measured by 752C UV-VIS spectrophotometer. Results Absorption spectrum of serum, plasma, hemoglobin, albumin,erythrocytes,lymphocytes,platelet were different, and so were the stations of their peak absorption value.All the maximal absorption was in the range of 200~300nm by ultraviolet wavelength, and all the absorbances fell down to the minimum within infrared range. Conclusion The findings will provide helpful bases for the blood irradiation wavelength in treatment of human diseases. Key words blood;lasers/ther use;spectrum analysis;spectrophotometry,infrared;spectrophotometry, ultraviolet
近年来,激光照射血液治疗方法在国内外逐步应用于临床,对治疗疾病具有一定效果〔1〕。 但国内外学术界认为对其基础性研究感有不足,应予加强〔2〕。据此作者针对人血液不同成 份对不同波长光的吸收特性这一重要问题进行了探讨。
材 料 与 方 法
一、材料 1.标本来源 ①正常人的血液。②福州市中心血站分离的血小板悬液。 2.试剂 ①260 g/L Na2SO4:无水Na2SO4 26 g加适量蒸馏水溶解后再加蒸馏水至100 ml。 ②Hank's液。③淋巴细胞分离液(上海荣盛生物试剂厂)。④血小板分离液(上海血液中心)。 ⑤肝素抗凝剂。 3.仪器 752C紫外可见分光光度计(上海第三分析仪器厂。光源:12V30W钨卤素灯、氘 灯。有关参数:波长精度±1 nm,波长重复性0.5 nm,吸光度精度±0.0004 nm,光度范围 -0.03~0.3 nm,最小分辨率0.0001 nm)。仪器经国家法定计量单位确认合格。 二、方法 1.分离血清,用生理盐水稀释。 2.血液加少量肝素抗凝,分离血浆,用生理盐水稀释。 3.[1] [2] 下一页 上一个医学论文: 不同剂量微波热凝后面神经变化的观察 下一个医学论文: 脊髓运动诱发电位在大鼠胚胎脊髓移植实验中的应用
|
|
|
|
|
|
|