大鼠痉挛性脑瘫模型建立的改进 |
|
吴珊鹏 罗永湘 熊 革
摘要 采用电毁损椎体束建立大鼠一侧肢体痉挛性瘫痪模型,通过自行设计的脑定位辅助装置安装在大鼠脑立体定位器上,增加了脑定位的准确性。同时采用了绝缘针进行刺激,减少了实验的干扰因素,从而使模型更为可靠。 关键词 脑瘫模型; 定位装置; 绝缘针
Medication of Spastic Cerebral Palsy in Rat
Wu Shanpeng, Luo Yongxiang, Xiong Ge Department of Orthopedics, The Second Affiliated Hospital, Fujian Medical University, Quanzhou 362000
Abstract The method for the establishment of one-side extremity spastic palsy model in rats by electronic injury of pyramidal tract was modified. The auto-designed cerebral positioning auxiliary set was used to mount the model rat on the cerebral steriotaxic instrument, so as to increase the accurate of the cerebral positioning. At the same time, a insulating needle was employed to conduct stimulation to decrease the disturbance factors of the experiment, so as to make the model reliable. Key words cerebral palsy model; positioning set; insulating set
目前在实验研究中尚无一规范的脑瘫模型可寻,为解决这一问题,1995年以来熊革[1]等人首先用电毁损方法初步建立了痉挛性脑瘫模型。我们在此基础上对模型进一步探索,摸索出了几点改进的方法。 1 模型的建立与改进方法 1.1 定位辅助装置的改进 ①大鼠脑定向器的改进:采用江湾Ⅰ型C大鼠脑立体定向器进行三维定位。为使脑定位更加精确,自行设计一定位辅助装置(附图)。此装置采用不锈钢制成,将它安装在脑定位器上,拧紧螺帽1、2,然后调整上板,使中线对准矢状缝,拧紧螺帽3、4,再将下板置于鼠头下方,调节调整板,使鼠头部刚好置于上、下板及双侧调整板间,拧紧螺帽5、6,检查上下板及双侧调整板尺度是否对称,然后通过中缝就可在鼠脑上钻孔。②绝缘针的制作(该方法由同济医科大学生理教研室提供):先将电针用酸或碱洗脱后烘干,然后向一恒温水箱内装水(约其容量的2/3),在水面上放一泡沫板,在板上放置一装有绝缘漆的烧杯, 将电针固定在可升降的支架上,然后将置电针入烧杯绝缘漆中,缓慢放出水箱内的水,烧杯随水下降,电针即均匀地涂上绝缘漆,再将电针置于电烤箱中烘干,取出后再用上法涂漆,如此反复4~6遍,最后用万用表检查绝缘情况。 1.2 模型的建立 采用熊革提出的方法建立模型:取Wistar大鼠10只,体重200~250 g,雌雄不拘,随机分成2组,每组5只。以戊巴比妥钠(30 mg/kg)腹腔麻醉后,1组卧位固定于大鼠脑立体定位器上,另1组使用定位辅助装置。沿颅顶矢状缝作纵行切口,暴露前囟,采用改良的de Groot定位系统,选择前囟后6.6 mm,矢状缝左侧1.0 mm,用小型电钻在颅板上钻孔,直径约2 mm,将阳极针电极(直径0.5 mm)垂直插入9.7 mm,阴极接鼠尾,通直流电刺激以毁损椎体束,刺激后拔出电极,关闭切口。并用10%活力碘消毒缝合创口。毁损后10只大鼠均当即处死,取脑组织进行HE染色检查。
附图 定位辅助装置
2 结果 结果显示:使用定位辅助装置组毁损部位均位于椎体束,而未使用组有2只毁损部位在椎体束旁。10只大鼠毁损部位均较局限于针尖部位,而针尖上方的脑组织正常。 3 讨论 脑瘫患者的治疗在临床上是一棘手的问题,尚有许多方面有待进一步研究。因此建立[1] [2] 下一页 上一个医学论文: 脑梗塞患者就医时间与瘫肢运动功能恢复的关系 下一个医学论文: 278例脑血管病患者生命质量评价
|
|
|
|
|
|
|